Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:BTCP2"

From cua_phy
Jump to navigation Jump to search
Line 20: Line 20:
 
| 11/06/2015 || Transmittance || Measurement of transverse transmittance.
 
| 11/06/2015 || Transmittance || Measurement of transverse transmittance.
 
|-
 
|-
| 11/13/2015 || Irradiation || Irradiated crystal, still with Cu attenuator in the machine (lower dose rate).
+
| 11/13/2015 || Irradiation || Irradiated crystal, still with 0.5mm Cu attenuator in the machine (lower dose rate). Several tests performed (learning the irradiation machine).
 +
|-
 +
| 11/20/2015 || Irradiation || Irradiated crystal, Cu attenuator removed (highest dose rate). 160keV photons, 6.0 mA, 10min.
 
|-
 
|-
 
| 11/23/2015 || Transmittance || Transverse transmittance with stepper motor, on the irradiated face and on the face perpendicular to that.
 
| 11/23/2015 || Transmittance || Transverse transmittance with stepper motor, on the irradiated face and on the face perpendicular to that.
Line 26: Line 28:
 
|}
 
|}
  
== Pictures xx/xx/xxxx ==
+
 
 +
== Pictures 11/23/2015 ==
 +
 
 +
{| border="0" style="text-align:center;" width="100%"
 +
|-
 +
| valign="top"|
 +
[[File:BTCP02_A.JPG|thumb|center|340px|xxxx.]]
 +
| valign="top"|
 +
[[File:BTCP02.JPG|thumb|center|340px|xxxx.]]
 +
|}
 +
 
 +
== Pictures 11/20/2015 ==
 +
 
 +
{| border="0" style="text-align:center;" width="100%"
 +
|-
 +
| valign="top"|
 +
[[File:BTCP02_A.JPG|thumb|center|340px|xxxx.]]
 +
| valign="top"|
 +
[[File:BTCP02.JPG|thumb|center|340px|xxxx.]]
 +
|}
 +
 
 +
== Pictures 11/13/2015 ==
 +
 
 +
{| border="0" style="text-align:center;" width="100%"
 +
|-
 +
| valign="top"|
 +
[[File:BTCP02_A.JPG|thumb|center|340px|xxxx.]]
 +
| valign="top"|
 +
[[File:BTCP02.JPG|thumb|center|340px|xxxx.]]
 +
|}
 +
 
 +
== Pictures 11/06/2015 (transverse transmittance) ==
  
 
{| border="0" style="text-align:center;" width="100%"  
 
{| border="0" style="text-align:center;" width="100%"  

Revision as of 14:04, 15 December 2015

⇐ Back to Crystal LOG
⇐ Back to Neutral Particle Spectrometer
⇐ Back to the Main_Page

Time LOG

BTCP 02 (##)
Date Description Comments
11/06/2015 Transmittance Measurement of transverse transmittance.
11/13/2015 Irradiation Irradiated crystal, still with 0.5mm Cu attenuator in the machine (lower dose rate). Several tests performed (learning the irradiation machine).
11/20/2015 Irradiation Irradiated crystal, Cu attenuator removed (highest dose rate). 160keV photons, 6.0 mA, 10min.
11/23/2015 Transmittance Transverse transmittance with stepper motor, on the irradiated face and on the face perpendicular to that.


Pictures 11/23/2015

xxxx.

Pictures 11/20/2015

xxxx.

Pictures 11/13/2015

xxxx.

Pictures 11/06/2015 (transverse transmittance)

xxxx.