Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCAJ18"

From cua_phy
Jump to navigation Jump to search
Line 35: Line 35:
 
|-
 
|-
 
| 03/04/2016 || Dimensions || Crystal's dimensions measured. Length and six points of width (3 in each face).
 
| 03/04/2016 || Dimensions || Crystal's dimensions measured. Length and six points of width (3 in each face).
 +
|-
 +
| 05/23/2016 || Transverse Transmittance Scan || Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s.
 
|}
 
|}
  

Revision as of 10:21, 23 May 2016

⇐ Back to Crystal LOG
⇐ Back to Neutral Particle Spectrometer
⇐ Back to the Main_Page

Time LOG

SICCA J18
Date Description Comments
12/14/2015 Pictures Documentation of crystal's conditions as it arrived at CUA.
12/15/2015 Thermal annealing Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
12/17/2015 Long. Transmittance Note: crystal NOT wrapped.
12/17/2015 Transverse Transmittance Scan at 360, 420, and 620nm.
12/18/2015 Irradiation 160 keV photons at 6mA, for 10min.
12/18/2015 Transverse Transmittance Scan at 360, 420, and 620nm after 30 min of irradiation.
01/05/2016 LY scan At 100ns, as described in run 3047.
03/04/2016 Transverse Transmittance At the center of the crystal, every nm from 200nm until 800nm. Sample: 1315
03/04/2016 Dimensions Crystal's dimensions measured. Length and six points of width (3 in each face).
05/23/2016 Transverse Transmittance Scan Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s.

Pictures at 12/14/2015

xxxx.
xxxx.