Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCA15"
Jump to navigation
Jump to search
(4 intermediate revisions by the same user not shown) | |||
Line 24: | Line 24: | ||
| 01/14/2016 || Transverse Transmittance || Spectral measurement. | | 01/14/2016 || Transverse Transmittance || Spectral measurement. | ||
|- | |- | ||
+ | | 06/01/2016 || Longitudinal Transmittance || Spectral measurement, Lambda 950 (integrating sphere). Wrapped crystal. | ||
+ | |- | ||
+ | | 06/02/2016 || Longitudinal Transmittance || Repeating measurement, to make sure alignment and other effects are indeed negligible in our setup. | ||
+ | |- | ||
+ | | 06/03/2016 || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour. | ||
+ | |- | ||
+ | | 06/06/2016 || Transverse Transmittance || Spectral measurement with Lambda 750. | ||
+ | |- | ||
+ | | 06/06/2016 || Transverse Transmittance || Spectral measurement with Lambda 950 - integrated sphere (may not be at exactly the same position). | ||
+ | |- | ||
+ | | 06/06/2016 || Crystal wrapped || 5 layers of teflon tape and 2 layers of black electrical tape. | ||
+ | |- | ||
+ | | 06/06/2016 || Longitudinal Transmittance || Spectral measurement with Lambda 950 - integrated sphere. | ||
+ | |} | ||
+ | |||
+ | == Transmittance measurements == | ||
+ | |||
+ | === Longitudinal transmittance === | ||
+ | |||
+ | {| border="0" style="text-align:center;" width="100%" | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:SICCA 15 LT BI.png|thumb|center|340px|Longitudinal transmittance measured at Lambda 750 (no integrating sphere). Crystal as arrived at CUA (probably irradiated at Caltech).]] | ||
+ | | valign="top"| | ||
+ | [[File:SICCA15_LT_sphere_anneal.png|thumb|center|340px|Longitudinal transmittance measured at Lambda 950 (with integrating sphere).]] | ||
|} | |} | ||
Latest revision as of 15:46, 6 June 2016
⇐ Back to Crystal LOG |
⇐ Back to Neutral Particle Spectrometer |
⇐ Back to the Main_Page |
Time LOG
Date | Description | Comments |
---|---|---|
01/10/2016 | Pictures | Documentation as arrived at CUA (received from Caltech). Name of the crystal was observed scratched on the face. Pictures 01/10/2016. |
01/14/2016 | Long. Transmittance | Crystal unwrapped. |
01/14/2016 | Transverse Transmittance | Spectral measurement. |
06/01/2016 | Longitudinal Transmittance | Spectral measurement, Lambda 950 (integrating sphere). Wrapped crystal. |
06/02/2016 | Longitudinal Transmittance | Repeating measurement, to make sure alignment and other effects are indeed negligible in our setup. |
06/03/2016 | Thermal annealing | Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour. |
06/06/2016 | Transverse Transmittance | Spectral measurement with Lambda 750. |
06/06/2016 | Transverse Transmittance | Spectral measurement with Lambda 950 - integrated sphere (may not be at exactly the same position). |
06/06/2016 | Crystal wrapped | 5 layers of teflon tape and 2 layers of black electrical tape. |
06/06/2016 | Longitudinal Transmittance | Spectral measurement with Lambda 950 - integrated sphere. |