Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCAJ20"

From cua_phy
Jump to navigation Jump to search
Line 44: Line 44:
 
|07/28/2016 || Transverse Transmittance || At 10cm. 200-800nm wavelength.
 
|07/28/2016 || Transverse Transmittance || At 10cm. 200-800nm wavelength.
 
|-
 
|-
| 07/28/2016 || X-Ray Irradiation || 160kV, 6.3mA, 70 minutes. 6290 R/min.
+
| 07/28/2016 || X-Ray Irradiation || 160kV 6.3mA 70 minutes. 14.16 cm for LabJack on shelf 8. 6290R/min ionization rate.
 
|-
 
|-
 
|07/28/2016 || Transverse Transmittance (spectrometer failure) || Unsuccessful measurement of transmittance.
 
|07/28/2016 || Transverse Transmittance (spectrometer failure) || Unsuccessful measurement of transmittance.

Revision as of 16:39, 8 August 2016

⇐ Back to Crystal LOG
⇐ Back to Neutral Particle Spectrometer
⇐ Back to the Main_Page

Time LOG

SICCA J20
Date Description Comments
12/14/2015 Pictures Documentation of crystal's conditions as it arrived at CUA.
12/15/2015 Thermal annealing Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
12/17/2015 Transverse Transmittance Scan at 360, 420, and 620nm.
12/18/2015 Irradiation 160 keV photons at 6mA, for 10min.
12/18/2015 Transverse Transmittance Scan at 360, 420, and 620nm after 30 min of irradiation.
01/07/2016 LY scan LY measurement with window width of 100ns, at 18oC (see run 3098). LY = 14.76 pe/MeV.
03/04/2016 Transverse Transmittance At the center of the crystal, every nm from 200nm until 800nm. Sample: 1313
03/04/2016 Dimensions Crystal's dimensions measured. Length and six points of width (3 in each face).
05/23/2016 Transverse Transmittance Scan Wavelengths: 200-800 nm. Sampling period: 0.6s, moving motor at 2mm/s.
07/08/2016 Longitudinal Transmittance Scan Wavelengths: 200-800 nm. Measured effect of off-center placement of crystal on transmittance. +1.3°, +2.3°, -1.3°, -2.3.
07/08/2016 Longitudinal Transmittance Scan Wavelengths: 200-800 nm. Measured light beam entering both end face of crystal in spectrometer. "flip" of crystal.
07/23/2016 Light Yield Run: 3246. 3 layers of teflon tape and 1 of electrical. ~50.000 incidents and ~18 degrees Celsius
07/28/2016 Transverse Transmittance At 10cm. 200-800nm wavelength.
07/28/2016 X-Ray Irradiation 160kV 6.3mA 70 minutes. 14.16 cm for LabJack on shelf 8. 6290R/min ionization rate.
07/28/2016 Transverse Transmittance (spectrometer failure) Unsuccessful measurement of transmittance.

Pictures at 12/14/2015

xxxx.
xxxx.

Light Yield

07/23/2016