Difference between revisions of "MainPage:Nuclear:KaonDetector:Pictures"
Jump to navigation
Jump to search
(28 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
− | |||
{|border="1" cellpadding="2" cellspacing="0" style="background-color:lightgray" | {|border="1" cellpadding="2" cellspacing="0" style="background-color:lightgray" | ||
| <font size="2">'''[[MainPage:Nuclear:KaonDetector|⇐ Back to Kaon Aerogel Detector]]'''</font> | | <font size="2">'''[[MainPage:Nuclear:KaonDetector|⇐ Back to Kaon Aerogel Detector]]'''</font> | ||
Line 6: | Line 5: | ||
|} | |} | ||
− | {| border="0" style="text-align:center;" width=" | + | == Detector installed in SHMS in Hall C at Jefferson Lab == |
− | |+'''Detector | + | |
+ | {| border="0" style="text-align:center;" width="100%" | ||
+ | |+'''Detector pictures and performance - detector is ready for beam!''' | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:IMG 1250.JPG|thumb|center|340px|Detector installed between heavy gas Cherenkov detector and second layer of hodoscopes in SHMS in Hall C at Jefferson LAB. View from Hall C floor.]] | ||
+ | | valign="top"| | ||
+ | [[File:Aerogel detecor shms 82016.jpg|thumb|center|240px|Sideview of detector as viewed from inside SHMS detector hut.]] | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:Aerogel detector performance 82016.png|thumb|center|340px|Performance of the detector - all channels are counting (cosmic test August 2016).]] | ||
+ | | valign="top"| | ||
+ | [[File:Light yield.png|thumb|center|340px|Light yield of the detector as measured in cosmic tests - lines indicate expected values.]] | ||
|- | |- | ||
| valign="top"| | | valign="top"| | ||
− | [[File: | + | [[File:IMG 1251.JPG|thumb|center|340px|SP-11 aerogel tray inner tray.]] |
| valign="top"| | | valign="top"| | ||
− | [[File: | + | [[File:IMG 0837.JPG|thumb|center|340px|Graduate student Jonathan Castellanos installing Gore reflector in the SP-11 aerogel tray to optimize light collection.]] |
+ | |} | ||
+ | |||
+ | |||
+ | == Assembly preparation and training at Jefferson Lab == | ||
+ | |||
+ | {| border="0" style="text-align:center;" width="100%" | ||
+ | |+'''Training to assembly the detector at Jefferson Lab''' | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:jlab_training_01.jpg|thumb|center|340px|Detector box received at Jefferson LAB.]] | ||
+ | | valign="top"| | ||
+ | [[File:jlab_training_02.jpg|thumb|center|340px|Transportation of the detector to the assembly room at JLab.]] | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:jlab_training_03.jpg|thumb|center|340px|PMTs are ready to be installed on the detector.]] | ||
+ | | valign="top"| | ||
+ | [[File:jlab_training_04.jpg|thumb|center|340px|Working with wires, that will prevent aerogel tiles to fall from the tray.]] | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:jlab_training_05.jpg|thumb|center|340px|A mesh of stainless steel wire were created. Here there wasn't aerogel in the tray yet, it was just for training how to place the wires stretched.]] | ||
+ | | valign="top"| | ||
+ | [[File:jlab_training_06.jpg|thumb|center|340px|Some aerogel tiles were stacked in the tray with a net of 150 micrometer wires placed to hold them.]] | ||
+ | |} | ||
+ | |||
+ | == Pre-assembly at CUA == | ||
+ | |||
+ | {| border="0" style="text-align:center;" width="100%" | ||
+ | |+'''Detector pre-assembly at CUA''' | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:assembly01.jpg|thumb|center|340px|Assembly of the Kaon Aerogel Detector at CUA. Top view of the detector, with one of the aerogel trays on the diffusion box.]] | ||
+ | | valign="top"| | ||
+ | [[File:assembly02.jpg|thumb|center|340px|View of the Kaon Aerogel Detector. It is be possible to introduce six extra PMTs on the top of the detector, if the experiment requires.]] | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:assembly03.jpg|thumb|center|340px]] | ||
+ | | valign="top"| | ||
+ | [[File:assembly04.jpg|thumb|center|340px]] | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:assembly05.jpg|thumb|center|340px]] | ||
+ | | valign="top"| | ||
+ | [[File:assembly06.jpg|thumb|center|340px]] | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:assembly07.jpg|thumb|center|340px]] | ||
+ | | valign="top"| | ||
+ | [[File:assembly08.jpg|thumb|center|340px|All the 14 sides PMTs were installed inside aluminum tubes and mu-metal tubes, in order to protect them mechanically and also shield from external magnetic fields.]] | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:assembly09.jpg|thumb|center|340px]] | ||
+ | | valign="top"| | ||
+ | [[File:assembly10.jpg|thumb|center|340px]] | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:assembly11.jpg|thumb|center|340px]] | ||
+ | | valign="top"| | ||
+ | [[File:assembly12.jpg|thumb|center|340px]] | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:assembly13.jpg|thumb|center|340px]] | ||
+ | | valign="top"| | ||
+ | [[File:KaonDetector_PreAssembly.png|thumb|center|340px]] | ||
+ | |- | ||
| valign="top"| | | valign="top"| | ||
− | [[File: | + | [[File:assembly15.jpg|thumb|center|340px]] |
| valign="top"| | | valign="top"| | ||
− | [[File: | + | [[File:Pre_Assembly.jpg|thumb|center|340px]] |
|} | |} |
Latest revision as of 11:43, 1 October 2016
⇐ Back to Kaon Aerogel Detector |
⇐ Back to the Main_Page |
Detector installed in SHMS in Hall C at Jefferson Lab