Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:CRYTUR01"
Jump to navigation
Jump to search
Line 14: | Line 14: | ||
</b></font> | </b></font> | ||
− | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date | + | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date |
+ | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Experimenter(s) | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments | ||
|- | |- | ||
− | | xx/xx/2015 || Wrapped || Preparing for light yield measurement. Approximately 5 layers of teflon tape, and 2 layers of black tape. | + | | xx/xx/2015 || Marco || Wrapped || Preparing for light yield measurement. Approximately 5 layers of teflon tape, and 2 layers of black tape. |
|- | |- | ||
− | | xx/xx/2015 || LY scan || ... | + | | xx/xx/2015 || Marco || LY scan || ... |
|- | |- | ||
− | | 12/14/2015 || unwrapped || Preparing for annealing. | + | | 12/14/2015 || Marco || unwrapped || Preparing for annealing. |
|- | |- | ||
− | | 12/14/2015 || Thermal annealing || Starting 11:00AM. Ramp up at 18oC/hour until 200oC, stay at 200oC for 10 hours, ramp down at -18oC/hour. | + | | 12/14/2015 || Marco || Thermal annealing || Starting 11:00AM. Ramp up at 18oC/hour until 200oC, stay at 200oC for 10 hours, ramp down at -18oC/hour. |
|- | |- | ||
− | | 12/17/2015 || Longitudinal Transmittance || After annealing. | + | | 12/17/2015 || Marco || Longitudinal Transmittance || After annealing. |
|- | |- | ||
− | | 07/15/2016 || Longitudinal Transmittance || Wavelength:200-800nm. | + | | 07/15/2016 || Summer Students || Longitudinal Transmittance || Wavelength:200-800nm. |
|- | |- | ||
− | | 08/11/2016 || LY scan || RUN:3411. Motor was lowered to approximately 5 cm down crystal. ~18oC. LY: 11.986 phe/MeV | + | | 08/11/2016 || Summer Students || LY scan || RUN:3411. Motor was lowered to approximately 5 cm down crystal. ~18oC. LY: 11.986 phe/MeV |
+ | |- | ||
+ | | 11/29/2016 || Salina || Light Yield || Run 3432: ~100K events; crystal wrapped with ~5 layers of teflon tape and 2 layers of black electrical tape. Steps of 20min, 1cm. T=18°C. LY = 8.23 ± 1.08 pe/MeV. Not enough statistics? Need to re-run with more stats (see pictures below) | ||
|} | |} | ||
Revision as of 21:25, 30 November 2016
⇐ Back to Crystal LOG |
⇐ Back to Neutral Particle Spectrometer |
⇐ Back to the Main_Page |
Time LOG
Date | Experimenter(s) | Description | Comments |
---|---|---|---|
xx/xx/2015 | Marco | Wrapped | Preparing for light yield measurement. Approximately 5 layers of teflon tape, and 2 layers of black tape. |
xx/xx/2015 | Marco | LY scan | ... |
12/14/2015 | Marco | unwrapped | Preparing for annealing. |
12/14/2015 | Marco | Thermal annealing | Starting 11:00AM. Ramp up at 18oC/hour until 200oC, stay at 200oC for 10 hours, ramp down at -18oC/hour. |
12/17/2015 | Marco | Longitudinal Transmittance | After annealing. |
07/15/2016 | Summer Students | Longitudinal Transmittance | Wavelength:200-800nm. |
08/11/2016 | Summer Students | LY scan | RUN:3411. Motor was lowered to approximately 5 cm down crystal. ~18oC. LY: 11.986 phe/MeV |
11/29/2016 | Salina | Light Yield | Run 3432: ~100K events; crystal wrapped with ~5 layers of teflon tape and 2 layers of black electrical tape. Steps of 20min, 1cm. T=18°C. LY = 8.23 ± 1.08 pe/MeV. Not enough statistics? Need to re-run with more stats (see pictures below) |