Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCAJ23"
Jump to navigation
Jump to search
(5 intermediate revisions by 3 users not shown) | |||
Line 15: | Line 15: | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date | ||
+ | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Experimenter(s) | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments | ||
|- | |- | ||
− | | 12/14/2015 || Pictures || Documentation of crystal's conditions as it arrived at CUA. | + | | 12/14/2015 || Marco || Pictures || Documentation of crystal's conditions as it arrived at CUA. |
|- | |- | ||
− | | 01/28/2016 || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour. | + | | 01/28/2016 || Marco || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour. |
|- | |- | ||
− | | 03/01/2016 || Light Yield || Run 3147: crystal wrapped with ~5 layers of teflon tape and 2 layers of black tape. Steps of 20min, 1cm. T=18oC. '''LY = 16.50 pe/MeV'''. | + | | 03/01/2016 || Marco || Light Yield || Run 3147: crystal wrapped with ~5 layers of teflon tape and 2 layers of black tape. Steps of 20min, 1cm. T=18oC. '''LY = 16.50 pe/MeV'''. |
|- | |- | ||
− | | 03/04/2016 || Transverse Transmittance || At the center of the crystal, every nm from 200nm until 800nm. Sample: 1310 | + | | 03/04/2016 || Marco || Transverse Transmittance || At the center of the crystal, every nm from 200nm until 800nm. Sample: 1310 |
|- | |- | ||
− | | 03/04/2016 || Dimensions || Crystal's dimensions measured. Length and six points of width (3 in each face). | + | | 03/04/2016 || Marco || Dimensions || Crystal's dimensions measured. Length and six points of width (3 in each face). |
|- | |- | ||
− | | 05/23/2016 || Transverse Transmittance Scan || Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s. | + | | 05/23/2016 || Marco || Transverse Transmittance Scan || Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s. |
|- | |- | ||
− | | 07/06/2016 || Longitudinal Transmittance Scan || Wavelengths: 200-800nm. Sampling period: 0.6s, moving motor at 2mm/s. | + | | 07/06/2016 || Summer Students || Longitudinal Transmittance Scan || Wavelengths: 200-800nm. Sampling period: 0.6s, moving motor at 2mm/s. |
|- | |- | ||
− | | 07/18/2016 || Transverse Transmittance Scan || Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s. | + | | 07/18/2016 || Summer Students || Transverse Transmittance Scan || Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s. |
|- | |- | ||
− | | 07/18/2016 || X-ray Radiation || 70 minutes. 160kV. 6mA. 70 minutes ? cm from beam origin. | + | | 07/18/2016 || Summer Students || X-ray Radiation || 70 minutes. 160kV. 6mA. 70 minutes ? cm from beam origin. |
|- | |- | ||
− | | 07/18/2016 || Transverse Transmittance Scan || Wavelengths: 200-800nm. Sampling period: 0.6s, moving motor at 2mm/s. | + | | 07/18/2016 || Summer Students || Transverse Transmittance Scan || Wavelengths: 200-800nm. Sampling period: 0.6s, moving motor at 2mm/s. |
|- | |- | ||
− | | 07/25/15 || X-ray Irradiation || 160kV 6.3mA | + | | 07/25/15 || Summer Students || X-ray Irradiation || 160kV 6.3mA 70 minutes. 14.16 cm for LabJack on shelf 8. 6290R/min ionization rate. |
|- | |- | ||
− | |07/25/16 || Transverse Transmittance || Wavelengths 200-800nm. | + | |07/25/16 || Summer Students || Transverse Transmittance || Wavelengths 200-800nm. |
|- | |- | ||
− | |07/25/16 || LED curing || 7 minutes at 3.5 V with 34 blue LEDs. | + | |07/25/16 || Summer Students || LED curing || 7 minutes at 3.5 V with 34 blue LEDs. |
|- | |- | ||
− | |07/25/16 || Transverse Transmittance || Wavelengths 200-800nm. | + | |07/25/16 || Summer Students || Transverse Transmittance || Wavelengths 200-800nm. |
|- | |- | ||
− | |07/25/16 || LED curing || 7 minutes at 3.5 V with 34 blue LEDs. | + | |07/25/16 || Summer Students || LED curing || 7 more minutes (14 total) at 3.5 V with 34 blue LEDs. |
|- | |- | ||
− | |07/25/16 || Transverse Transmittance || Wavelengths 200-800nm. | + | |07/25/16 || Summer Students || Transverse Transmittance || Wavelengths 200-800nm. |
+ | |- | ||
+ | |08/08/2016 || Summer Students || Transverse Transmittance || Wavelengths 200-800nm. 10cm down crystal. Want to see if crystal recovers after 9 days of sitting in its casing. | ||
|} | |} | ||
Line 69: | Line 72: | ||
| valign="top"| | | valign="top"| | ||
[[File:SICCAJ23.JPG|thumb|center|340px|xxxx.]] | [[File:SICCAJ23.JPG|thumb|center|340px|xxxx.]] | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | ==Radiation Hardness== | ||
+ | {|border="0" style="text-align:center;" width="100%" | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:J23_radiation_hardness_redo.png|thumb|left|340px| 07/29/2016]] | ||
+ | |} | ||
+ | |||
+ | ==LED curing== | ||
+ | {|border="0" style="text-align:center;" width="100%" | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:J23_LED_curing.png|thumb|left|340px| 07/29/2016]] | ||
|} | |} |
Latest revision as of 00:49, 8 January 2017
⇐ Back to Crystal LOG |
⇐ Back to Neutral Particle Spectrometer |
⇐ Back to the Main_Page |
Time LOG
Date | Experimenter(s) | Description | Comments |
---|---|---|---|
12/14/2015 | Marco | Pictures | Documentation of crystal's conditions as it arrived at CUA. |
01/28/2016 | Marco | Thermal annealing | Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour. |
03/01/2016 | Marco | Light Yield | Run 3147: crystal wrapped with ~5 layers of teflon tape and 2 layers of black tape. Steps of 20min, 1cm. T=18oC. LY = 16.50 pe/MeV. |
03/04/2016 | Marco | Transverse Transmittance | At the center of the crystal, every nm from 200nm until 800nm. Sample: 1310 |
03/04/2016 | Marco | Dimensions | Crystal's dimensions measured. Length and six points of width (3 in each face). |
05/23/2016 | Marco | Transverse Transmittance Scan | Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s. |
07/06/2016 | Summer Students | Longitudinal Transmittance Scan | Wavelengths: 200-800nm. Sampling period: 0.6s, moving motor at 2mm/s. |
07/18/2016 | Summer Students | Transverse Transmittance Scan | Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s. |
07/18/2016 | Summer Students | X-ray Radiation | 70 minutes. 160kV. 6mA. 70 minutes ? cm from beam origin. |
07/18/2016 | Summer Students | Transverse Transmittance Scan | Wavelengths: 200-800nm. Sampling period: 0.6s, moving motor at 2mm/s. |
07/25/15 | Summer Students | X-ray Irradiation | 160kV 6.3mA 70 minutes. 14.16 cm for LabJack on shelf 8. 6290R/min ionization rate. |
07/25/16 | Summer Students | Transverse Transmittance | Wavelengths 200-800nm. |
07/25/16 | Summer Students | LED curing | 7 minutes at 3.5 V with 34 blue LEDs. |
07/25/16 | Summer Students | Transverse Transmittance | Wavelengths 200-800nm. |
07/25/16 | Summer Students | LED curing | 7 more minutes (14 total) at 3.5 V with 34 blue LEDs. |
07/25/16 | Summer Students | Transverse Transmittance | Wavelengths 200-800nm. |
08/08/2016 | Summer Students | Transverse Transmittance | Wavelengths 200-800nm. 10cm down crystal. Want to see if crystal recovers after 9 days of sitting in its casing. |
Transmittance measurements
Pictures at 12/14/2015