Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCAJ17"
Jump to navigation
Jump to search
(8 intermediate revisions by 4 users not shown) | |||
Line 15: | Line 15: | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date | ||
+ | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Experimenter | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments | ||
|- | |- | ||
− | | 12/14/2015 || Pictures || Documentation of crystal's conditions as it arrived at CUA. | + | | 12/14/2015 || Marco || Pictures || Documentation of crystal's conditions as it arrived at CUA. |
|- | |- | ||
− | | 12/14/2015 || Wrapped || Preparing for light yield measurement. Approximately 5 layers of teflon tape, and 2 layers of black tape. | + | | 12/14/2015 || Marco || Wrapped || Preparing for light yield measurement. Approximately 5 layers of teflon tape, and 2 layers of black tape. |
|- | |- | ||
− | | 12/17/2015 || Long. Transmittance || Note: not annealed, crystal wrapped. | + | | 12/17/2015 || Marco || Long. Transmittance || Note: not annealed, crystal wrapped. |
|- | |- | ||
− | | 01/08/2016 || LY scan || LY measurement with window width of 100ns, at 18oC (see run 3100). LY = 24.28 pe/MeV. | + | | 01/08/2016 || Marco || LY scan || LY measurement with window width of 100ns, at 18oC (see run 3100). LY = 24.28 pe/MeV. |
|- | |- | ||
− | | 02/01/2016 || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour. | + | | 02/01/2016 || Marco || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour. |
|- | |- | ||
− | | 03/04/2016 || Transverse Transmittance || At the center of the crystal, every nm from 200nm until 800nm. Sample: 1316 | + | | 03/04/2016 || Marco || Transverse Transmittance || At the center of the crystal, every nm from 200nm until 800nm. Sample: 1316 |
|- | |- | ||
− | | 03/04/2016 || Dimensions || Crystal's dimensions measured. Length and six points of width (3 in each face). | + | | 03/04/2016 || Marco || Dimensions || Crystal's dimensions measured. Length and six points of width (3 in each face). |
|- | |- | ||
− | | 05/23/2016 || Transverse Transmittance Scan || Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s. | + | | 05/23/2016 || Marco || Transverse Transmittance Scan || Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s. |
|- | |- | ||
− | | 05/23/2016 || Irradiation || Placed at Co-60 setup at 4:05PM, around 1cm from source (~95mGy/h). | + | | 05/23/2016 || Marco || Irradiation || Placed at Co-60 setup at 4:05PM, around 1cm from source (~95mGy/h). |
+ | |- | ||
+ | | 12/20/2016 || TH || Light Yield || run 3506: '''25.94 pe/MeV'''. Note: not a good fit to SEP and signal with the nominal analysis code and without adjusting fit limits - this needs to be re-done carefully. | ||
+ | |- | ||
+ | | 01/06/2017 || Rich/TH || Irradiation X-ray || 160 kV, 6.2mA, 30 min. Absorption coefficient at 400nm: 1.58 m-1 | ||
+ | |} | ||
+ | |||
+ | == Transmittance measurements == | ||
+ | |||
+ | {| border="0" style="text-align:center;" width="100%" | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:SICCA J17 LT.png|thumb|center|340px|Longitudinal transmittance measured at Lambda 750 (no integrating sphere).]] | ||
+ | | valign="top"| | ||
|} | |} | ||
Latest revision as of 19:07, 8 January 2017
⇐ Back to Crystal LOG |
⇐ Back to Neutral Particle Spectrometer |
⇐ Back to the Main_Page |
Time LOG
Date | Experimenter | Description | Comments |
---|---|---|---|
12/14/2015 | Marco | Pictures | Documentation of crystal's conditions as it arrived at CUA. |
12/14/2015 | Marco | Wrapped | Preparing for light yield measurement. Approximately 5 layers of teflon tape, and 2 layers of black tape. |
12/17/2015 | Marco | Long. Transmittance | Note: not annealed, crystal wrapped. |
01/08/2016 | Marco | LY scan | LY measurement with window width of 100ns, at 18oC (see run 3100). LY = 24.28 pe/MeV. |
02/01/2016 | Marco | Thermal annealing | Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour. |
03/04/2016 | Marco | Transverse Transmittance | At the center of the crystal, every nm from 200nm until 800nm. Sample: 1316 |
03/04/2016 | Marco | Dimensions | Crystal's dimensions measured. Length and six points of width (3 in each face). |
05/23/2016 | Marco | Transverse Transmittance Scan | Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s. |
05/23/2016 | Marco | Irradiation | Placed at Co-60 setup at 4:05PM, around 1cm from source (~95mGy/h). |
12/20/2016 | TH | Light Yield | run 3506: 25.94 pe/MeV. Note: not a good fit to SEP and signal with the nominal analysis code and without adjusting fit limits - this needs to be re-done carefully. |
01/06/2017 | Rich/TH | Irradiation X-ray | 160 kV, 6.2mA, 30 min. Absorption coefficient at 400nm: 1.58 m-1 |