Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCAJ35"

From cua_phy
Jump to navigation Jump to search
 
Line 15: Line 15:
  
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date  
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date  
 +
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Experimenter(s)
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description  
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description  
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments
 
|-
 
|-
| 03/17/2016 || Pictures || Documentation of crystal's conditions as it arrived at CUA.
+
| 03/17/2016 || Marco || Pictures || Documentation of crystal's conditions as it arrived at CUA.
 
|-
 
|-
| 03/18/2016 || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
+
| 03/18/2016 || Marco || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
 
|-
 
|-
| 04/24/2016 || Light Yield || Run 3196: crystal wrapped with ~5 layers of teflon tape and 2 layers of black tape. Steps of 20min, 1cm. T=18oC. LY = 16.1161 ± 0.566 pe/MeV.
+
| 04/24/2016 || Marco || Light Yield || Run 3196: crystal wrapped with ~5 layers of teflon tape and 2 layers of black tape. Steps of 20min, 1cm. T=18oC. LY = 16.1161 ± 0.566 pe/MeV.
 
|-
 
|-
| 05/17/2016 || Transverse Transmittance || At the center of the crystal, every nm from 200nm until 800nm. Sample: 1351
+
| 05/17/2016 || Marco || Transverse Transmittance || At the center of the crystal, every nm from 200nm until 800nm. Sample: 1351
 
|-
 
|-
| 05/20/2016 || Transverse Transmittance Scan || Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s.
+
| 05/20/2016 || Marco || Transverse Transmittance Scan || Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s.
 
|-
 
|-
| 07/12/2016 || Longitudinal Transmittance Scan || Wavelengths: 200-800 nm. Sampling period: 0.6s, moving motor at 2mm/s.
+
| 07/12/2016 || Marco || Longitudinal Transmittance Scan || Wavelengths: 200-800 nm. Sampling period: 0.6s, moving motor at 2mm/s.
 
|}
 
|}
  

Latest revision as of 11:40, 20 September 2017

⇐ Back to Crystal LOG
⇐ Back to Neutral Particle Spectrometer
⇐ Back to the Main_Page

Time LOG

SICCA J35
Date Experimenter(s) Description Comments
03/17/2016 Marco Pictures Documentation of crystal's conditions as it arrived at CUA.
03/18/2016 Marco Thermal annealing Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
04/24/2016 Marco Light Yield Run 3196: crystal wrapped with ~5 layers of teflon tape and 2 layers of black tape. Steps of 20min, 1cm. T=18oC. LY = 16.1161 ± 0.566 pe/MeV.
05/17/2016 Marco Transverse Transmittance At the center of the crystal, every nm from 200nm until 800nm. Sample: 1351
05/20/2016 Marco Transverse Transmittance Scan Wavelengths: 360nm, 420nm, 620nm. Sampling period: 0.6s, moving motor at 2mm/s.
07/12/2016 Marco Longitudinal Transmittance Scan Wavelengths: 200-800 nm. Sampling period: 0.6s, moving motor at 2mm/s.

Pictures at 03/17/2016

xxxx.
xxxx.