Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCA02"

From cua_phy
Jump to navigation Jump to search
 
(5 intermediate revisions by one other user not shown)
Line 15: Line 15:
  
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date  
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date  
 +
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Experimenter(s)
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description  
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description  
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments
 
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments
 
|-
 
|-
| 12/09/2015 || unwrapped || Unwrapped as arrived at CUA. Cracks observed on the face - see [[MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCA02#Pictures_at_12.2F09.2F2015|Pictures 12/09/2015]].
+
| 12/09/2015 || Marco || unwrapped || Unwrapped as arrived at CUA. Cracks observed on the face - see [[MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCA02#Pictures_at_12.2F09.2F2015|Pictures 12/09/2015]].
 
|-
 
|-
| 12/10/2015 || Thermal annealing || Starting 10:30AM. Ramp up at 18oC/hour until 200oC, stay at 200oC for 10 hours, ramp down at -18oC/hour.
+
| 12/10/2015 || Marco || Thermal annealing || Starting 10:30AM. Ramp up at 18oC/hour until 200oC, stay at 200oC for 10 hours, ramp down at -18oC/hour.
 
|-
 
|-
| 12/11/2015 || Wrapped || Preparing for light yield measurement. Approximately 5 layers of teflon tape, and 2 layers of black tape - see [[MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCA02#Pictures_at_12.2F11.2F2015|Pictures 12/11/2015]].
+
| 12/11/2015 || Marco || Wrapped || Preparing for light yield measurement. Approximately 5 layers of teflon tape, and 2 layers of black tape - see [[MainPage:Nuclear:NPS:PWO:CrystalLOG:SICCA02#Pictures_at_12.2F11.2F2015|Pictures 12/11/2015]].
 
|-
 
|-
| 12/14/2015 || LY scan || Measurement of LY along crystal. Cracked area far apart from PMT; cracked face opposite to the radioactive side. More details in the LOGBOOK, runs 2942..
+
| 12/14/2015 || Marco || LY scan || Measurement of LY along crystal. Cracked area far apart from PMT; cracked face opposite to the radioactive side. More details in the LOGBOOK, runs 2942..
 
|-
 
|-
| 12/xx/2015 || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
+
| 12/xx/2015 || Marco || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
 
|-
 
|-
| 12/17/2015 || Long. Transmittance || Crystal wrapped.
+
| 12/17/2015 || Marco || Long. Transmittance || Crystal wrapped.
 
|-
 
|-
| 12/17/2015 || Unwrapped || Preparing for transverse transmittance.
+
| 12/17/2015 || Marco || Unwrapped || Preparing for transverse transmittance.
 
|-
 
|-
| 12/17/2015 || Transverse Transmittance || Scan at 360, 420, and 620nm.
+
| 12/17/2015 || Marco || Transverse Transmittance || Scan at 360, 420, and 620nm.
 
|-
 
|-
| 12/18/2015 || Irradiation || 160 keV photons at 6mA, for 10min.
+
| 12/18/2015 || Marco || Irradiation || 160 keV photons at 6mA, for 10min.
 
|-
 
|-
| 12/18/2015 || Transverse Transmittance || Scan at 360, 420, and 620nm after 30 min from irradiation.
+
| 12/18/2015 || Marco || Transverse Transmittance || Scan at 360, 420, and 620nm after 30 min from irradiation.
 
|-
 
|-
| 01/14/2016 || Transverse Transmittance || Scan at 420nm (scan setup realigned).
+
| 01/14/2016 || Marco || Transverse Transmittance || Scan at 420nm (scan setup realigned).
 
|-
 
|-
| 01/14/2016 || Irradiation || 160 keV photons at 6mA, for 20min.
+
| 01/14/2016 || Marco || Irradiation || 160 keV photons at 6mA, for 20min.
 
|-
 
|-
| 01/14/2016 || Transverse Transmittance || Scan at 420nm after 30 min from irradiation.
+
| 01/14/2016 || Marco || Transverse Transmittance || Scan at 420nm after 30 min from irradiation.
 
|-
 
|-
| 01/14/2016 || Transverse Transmittance || Spectral measurement.
+
| 01/14/2016 || Marco ||Transverse Transmittance || Spectral measurement.
 
|-
 
|-
| 02/01/2016 || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
+
| 02/01/2016 || Marco || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
 
|-
 
|-
| 05/16/2016 || Transverse Transmittance || Scan at 420nm, 360nm, 650nm.
+
| 05/16/2016 || Salina || Transverse Transmittance || Scan at 420nm, 360nm, 650nm.
 
|-
 
|-
| 05/16/2016 || Irradiation || 700 mGy of Co-60 at dose rates of ~70 mGy/h (10 h) - source at 3cm from crystal. Cylinder of 1 inch per 2cm irradiated.
+
| 05/16/2016 || Marco || Irradiation || 700 mGy of Co-60 at dose rates of ~70 mGy/h (10 h) - source at 3cm from crystal. Cylinder of 1 inch per 2cm irradiated.
 
|-
 
|-
| 05/17/2016 || Transverse Transmittance || Scan at 420nm after irradiation.
+
| 05/17/2016 || Salina || Transverse Transmittance || Scan at 420nm after irradiation.
 
|-  
 
|-  
| 05/17/2016 || Irradiation || 840 mGy of Co-60 at dose rates of ~70 mGy/h (12 h). Cylinder of 1 inch per 2cm irradiated.
+
| 05/17/2016 || Marco || Irradiation || 840 mGy of Co-60 at dose rates of ~70 mGy/h (12 h). Cylinder of 1 inch per 2cm irradiated.
 
|-  
 
|-  
| 05/18/2016 || Irradiation || 11200 mGy (total 12Gy with previous irrad) of Co-60 at dose rates of ~105 mGy/h (xx h) - source at 1cm from crystal. Cylinder of 1 inch per 2cm irradiated.
+
| 05/18/2016 || Marco || Irradiation || 11200 mGy (total 12Gy with previous irrad) of Co-60 at dose rates of ~105 mGy/h (xx h) - source at 1cm from crystal. Cylinder of 1 inch per 2cm irradiated.
 
|-
 
|-
| 05/24/2016 || Transverse Transmittance || Spectral, at center (position where irradiated with Co-60). In preparation for x-ray machine.
+
| 05/24/2016 || Marco || Transverse Transmittance || Spectral, at center (position where irradiated with Co-60). In preparation for x-ray machine.
 
|-
 
|-
| 05/24/2016 || Irradiation (x-ray) || 1h @ 160kV @ 6mA.
+
| 05/24/2016 || Marco ||  Irradiation (x-ray) || 90min @ 160kV @ 6mA.
 +
|-
 +
| 05/24/2016 || Marco || Transverse Transmittance || At same position as before, after about 5min of irradiation in x-ray machine.
 +
|-
 +
| 05/24/2016 || Marco || Irradiation (x-ray) || 180min @ 160kV @ 6mA.
 +
|-
 +
| 06/03/2016 || Marco || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
 +
|-
 +
| 06/06/2016 || Marco || Transverse Transmittance || Spectral measurement with Lambda 750.
 +
|-
 +
| 06/06/2016 || Marco || Transverse Transmittance || Spectral measurement with Lambda 950 - integrated sphere (may not be at exactly the same position).
 +
|-
 +
| 06/06/2016 || Marco || Crystal wrapped || 5 layers of teflon tape and 2 layers of black electrical tape.
 +
|-
 +
| 06/06/2016 || Marco || Longitudinal Transmittance || Spectral measurement with Lambda 950 - integrated sphere.
 +
|}
 +
 
 +
== Transmittance measurements ==
 +
 
 +
{| border="0" style="text-align:center;" width="100%"
 +
|-
 +
| valign="top"|
 +
[[File:SICCA 2 LT.png|thumb|center|340px|Longitudinal transmittance measured at Lambda 750 (no integrating sphere).]]
 +
| valign="top"|
 
|}
 
|}
  

Latest revision as of 12:04, 20 September 2017

⇐ Back to Crystal LOG
⇐ Back to Neutral Particle Spectrometer
⇐ Back to the Main_Page

Time LOG

SICCA 02
Date Experimenter(s) Description Comments
12/09/2015 Marco unwrapped Unwrapped as arrived at CUA. Cracks observed on the face - see Pictures 12/09/2015.
12/10/2015 Marco Thermal annealing Starting 10:30AM. Ramp up at 18oC/hour until 200oC, stay at 200oC for 10 hours, ramp down at -18oC/hour.
12/11/2015 Marco Wrapped Preparing for light yield measurement. Approximately 5 layers of teflon tape, and 2 layers of black tape - see Pictures 12/11/2015.
12/14/2015 Marco LY scan Measurement of LY along crystal. Cracked area far apart from PMT; cracked face opposite to the radioactive side. More details in the LOGBOOK, runs 2942..
12/xx/2015 Marco Thermal annealing Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
12/17/2015 Marco Long. Transmittance Crystal wrapped.
12/17/2015 Marco Unwrapped Preparing for transverse transmittance.
12/17/2015 Marco Transverse Transmittance Scan at 360, 420, and 620nm.
12/18/2015 Marco Irradiation 160 keV photons at 6mA, for 10min.
12/18/2015 Marco Transverse Transmittance Scan at 360, 420, and 620nm after 30 min from irradiation.
01/14/2016 Marco Transverse Transmittance Scan at 420nm (scan setup realigned).
01/14/2016 Marco Irradiation 160 keV photons at 6mA, for 20min.
01/14/2016 Marco Transverse Transmittance Scan at 420nm after 30 min from irradiation.
01/14/2016 Marco Transverse Transmittance Spectral measurement.
02/01/2016 Marco Thermal annealing Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
05/16/2016 Salina Transverse Transmittance Scan at 420nm, 360nm, 650nm.
05/16/2016 Marco Irradiation 700 mGy of Co-60 at dose rates of ~70 mGy/h (10 h) - source at 3cm from crystal. Cylinder of 1 inch per 2cm irradiated.
05/17/2016 Salina Transverse Transmittance Scan at 420nm after irradiation.
05/17/2016 Marco Irradiation 840 mGy of Co-60 at dose rates of ~70 mGy/h (12 h). Cylinder of 1 inch per 2cm irradiated.
05/18/2016 Marco Irradiation 11200 mGy (total 12Gy with previous irrad) of Co-60 at dose rates of ~105 mGy/h (xx h) - source at 1cm from crystal. Cylinder of 1 inch per 2cm irradiated.
05/24/2016 Marco Transverse Transmittance Spectral, at center (position where irradiated with Co-60). In preparation for x-ray machine.
05/24/2016 Marco Irradiation (x-ray) 90min @ 160kV @ 6mA.
05/24/2016 Marco Transverse Transmittance At same position as before, after about 5min of irradiation in x-ray machine.
05/24/2016 Marco Irradiation (x-ray) 180min @ 160kV @ 6mA.
06/03/2016 Marco Thermal annealing Ramp up at 18oC/hour up to 200oC. Stays for 10 hours and ramp down at 18oC/hour.
06/06/2016 Marco Transverse Transmittance Spectral measurement with Lambda 750.
06/06/2016 Marco Transverse Transmittance Spectral measurement with Lambda 950 - integrated sphere (may not be at exactly the same position).
06/06/2016 Marco Crystal wrapped 5 layers of teflon tape and 2 layers of black electrical tape.
06/06/2016 Marco Longitudinal Transmittance Spectral measurement with Lambda 950 - integrated sphere.

Transmittance measurements

Longitudinal transmittance measured at Lambda 750 (no integrating sphere).

Pictures at 12/09/2015

xxxx.
xxxx.

Pictures at 12/11/2015

xxxx.
xxxx.
xxxx.