Difference between revisions of "MainPage:Nuclear:NPS:PWO:CrystalLOG:BTCP2"
Jump to navigation
Jump to search
(9 intermediate revisions by one other user not shown) | |||
Line 15: | Line 15: | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:10%;" | Date | ||
+ | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Experimenter(s) | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:15%;" | Description | ||
! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments | ! "background:#f5f5f5;" style="text-align:center; background:lavender; font-weight:bold; width:75%;" | Comments | ||
|- | |- | ||
− | | 11/06/2015 || Transmittance || Measurement of transverse transmittance. | + | | 11/06/2015 || Marco || Transmittance || Measurement of transverse transmittance. |
|- | |- | ||
− | | 11/13/2015 || Irradiation || Irradiated crystal, still with Cu attenuator in the machine (lower dose rate). | + | | 11/13/2015 || Marco || Irradiation || Irradiated crystal, still with 0.5mm Cu attenuator in the machine (lower dose rate). Several tests performed (learning the irradiation machine). |
|- | |- | ||
− | | 11/ | + | | 11/20/2015 || Marco || Irradiation || Irradiated crystal, Cu attenuator removed (highest dose rate). 160keV photons, 6.0 mA, 10min. |
|- | |- | ||
+ | | 11/23/2015 || Marco || Transmittance || Transverse transmittance with stepper motor, on the irradiated face and on the face perpendicular to that. | ||
+ | |- | ||
+ | | 12/17/2015 || Marco || Longitudinal Transmittance || Wrapped. | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | == Transmittance measurements == | ||
+ | |||
+ | {| border="0" style="text-align:center;" width="100%" | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:BTCP 2 LT.png|thumb|center|340px|Longitudinal transmittance measured at Lambda 750 (no integrating sphere).]] | ||
+ | | valign="top"| | ||
+ | |} | ||
+ | |||
+ | == Pictures 11/23/2015 (transverse transmittance) == | ||
+ | |||
+ | {| border="0" style="text-align:center;" width="100%" | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:BTCP02_G.JPG|thumb|center|340px|xxxx.]] | ||
+ | | valign="top"| | ||
+ | [[File:BTCP02_H.JPG|thumb|center|340px|xxxx.]] | ||
+ | |} | ||
+ | |||
+ | == Pictures 11/20/2015 (irradiation) == | ||
+ | |||
+ | {| border="0" style="text-align:center;" width="100%" | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:BTCP02_E.JPG|thumb|center|340px|xxxx.]] | ||
+ | | valign="top"| | ||
+ | [[File:NPSIconLightYield.jpg|thumb|center|340px|xxxx.]] | ||
+ | |} | ||
+ | |||
+ | == Pictures 11/13/2015 (irradiation) == | ||
+ | |||
+ | {| border="0" style="text-align:center;" width="100%" | ||
+ | |- | ||
+ | | valign="top"| | ||
+ | [[File:BTCP02_C.JPG|thumb|center|340px|xxxx.]] | ||
+ | | valign="top"| | ||
+ | [[File:PbF2cube_D.JPG|thumb|center|340px|xxxx.]] | ||
|} | |} | ||
− | == Pictures | + | == Pictures 11/06/2015 (transverse transmittance) == |
{| border="0" style="text-align:center;" width="100%" | {| border="0" style="text-align:center;" width="100%" | ||
Line 33: | Line 77: | ||
[[File:BTCP02_A.JPG|thumb|center|340px|xxxx.]] | [[File:BTCP02_A.JPG|thumb|center|340px|xxxx.]] | ||
| valign="top"| | | valign="top"| | ||
− | [[File: | + | [[File:BTCP02_B.JPG|thumb|center|340px|xxxx.]] |
|} | |} |
Latest revision as of 12:08, 20 September 2017
⇐ Back to Crystal LOG |
⇐ Back to Neutral Particle Spectrometer |
⇐ Back to the Main_Page |
Time LOG
Date | Experimenter(s) | Description | Comments |
---|---|---|---|
11/06/2015 | Marco | Transmittance | Measurement of transverse transmittance. |
11/13/2015 | Marco | Irradiation | Irradiated crystal, still with 0.5mm Cu attenuator in the machine (lower dose rate). Several tests performed (learning the irradiation machine). |
11/20/2015 | Marco | Irradiation | Irradiated crystal, Cu attenuator removed (highest dose rate). 160keV photons, 6.0 mA, 10min. |
11/23/2015 | Marco | Transmittance | Transverse transmittance with stepper motor, on the irradiated face and on the face perpendicular to that. |
12/17/2015 | Marco | Longitudinal Transmittance | Wrapped. |