− | | 11/ | + | | 11/8/2017 || Arshak || Visual Inspection || Documentation of crystal's conditions as it arrived at JLab. |
|- | |- | ||
− | | 11/ | + | | 11/15/2017 || Tanja || Visual Inspection || Documentation of crystal's conditions as it arrived at CUA. |
|- | |- | ||
| 11/XX/2017 || Tanja || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stay for 10 hours and ramp down at 18oC/hour. | | 11/XX/2017 || Tanja || Thermal annealing || Ramp up at 18oC/hour up to 200oC. Stay for 10 hours and ramp down at 18oC/hour. | ||
Line 39: | Line 39: | ||
[[File:PWO-SICCAS-box2-5-6.png|thumb|center|340px|xxxx.]] | [[File:PWO-SICCAS-box2-5-6.png|thumb|center|340px|xxxx.]] | ||
| valign="top"| | | valign="top"| | ||
− | [[File:IMG .JPG|thumb|center|340px|xxxx.]] | + | [[File:IMG 0365.JPG|thumb|center|340px|xxxx.]] |
|- | |- | ||
| valign="top"| | | valign="top"| | ||
− | [[File:IMG .JPG|thumb|center|340px|xxxx.]] | + | [[File:IMG 0366.JPG|thumb|center|340px|xxxx.]] |
| valign="top"| | | valign="top"| | ||
[[File:SICCAS_5203.JPG|thumb|center|340px|xxxx.]] | [[File:SICCAS_5203.JPG|thumb|center|340px|xxxx.]] |
Revision as of 18:49, 15 November 2017
⇐ Back to Crystal LOG |
⇐ Back to Neutral Particle Spectrometer |
⇐ Back to the Main_Page |
Time LOG
Pictures 11/XX/2017
Date | Experimenter | Description | Comments |
---|---|---|---|
11/8/2017 | Arshak | Visual Inspection | Documentation of crystal's conditions as it arrived at JLab. |
11/15/2017 | Tanja | Visual Inspection | Documentation of crystal's conditions as it arrived at CUA. |
11/XX/2017 | Tanja | Thermal annealing | Ramp up at 18oC/hour up to 200oC. Stay for 10 hours and ramp down at 18oC/hour. |
11/XX/2017 | Tanja | Longitudinal Transmittance Scan | Wavelengths: 200-800nm. |
11/X/2017 | Tanja | Wrapped | Preparing for light yield measurement. 3 layers of teflon tape, and 2 layers of black tape. |
11/XX/2017 | Tanja | LY scan | Measurement of LY along crystal. More details in the LOGBOOK, runs xx.. |
File:SICCAS 5203.JPG xxxx. |
Longitudinal and Transverse Transmittance (TT)
Light Yield
File:5203-100nsgw.png 11/XX/2017 |
Radiation Hardness
File:5203 radiation hardness.png XX/XX/XXXX. Wait time to transmittance measurement ~15 minutes. |