MainPage:Nuclear:Summer2012:RefractiveIndex

From cua_phy
Jump to navigation Jump to search
⇐ Back to Summer 2012 page
⇐ Back to the Main_Page
A red laser is visible as it passes through an aerogel tile during one of our measurements for the index of refraction.

About Our Work

The index of refraction is a property of a material which dictates how quickly light travels through that material. As light passes through a material with one index of refraction to a material with a different index of refraction, the light changes speed and "bends" as it changes mediums. When light travels from a material with a low index of refraction to one with a high index of refraction, the light is bent toward the normal, and vice verse. We are working to measure the index of refraction of aerogel to a very high degree of precision. This value is significant because the aerogel will be used as a particle identification system in the Kaon Aerogel Detector at JLab to distinguish between Kaons and Protons according to their momentum.

Measurement Set-up

We use a set-up with graph paper, a laser, aerogel, and measuring tools. The index of refraction can be measured using only the incident angle, the distance between the aerogel and a screen, and the amount the light is shifted on the screen after the aerogel is placed in front of the laser.

A picture of the index of refraction measurements. You can se the displacement of the laser by the aerogel


The equation for calculating gamma based on the incident angle is ɣ = ɑ - (π/2) + arcsin[n•sin((π/2)-arcsin(sin(ɑ)/n))]

We can then use this equation to calculate the index of refraction; n = (sin2(ɑ) + cos2(ɣ - ɑ))½

Finding Error

An image of the uncertainty propagation calculator we have been using.
Several measurements using image analysis on our aerogel tiles.

We have worked meticulously to reduce the error in our measurements and have significantly reduced our uncertainty. The next step is to include error propagation in our calculations which will account for the accumulative uncertainties of multiple measurements. We have done the uncertainty propagation by hand, but find it much more convenient to use a computer program to help with the tedious calculations. To help further reduce our error, we have started using image analysis software. This allows us to take a picture of our aerogel sample and very accurately measure the incident angle of our laser.

Results

We have done several tests and all of them have fairly small error and are very close to the expected value, 1.03.

First-five-tests.jpg

The average uncertainty in the graph is 0.0005616, however we have not yet included uncertainty propagation in these results. Uncertainty propagation will provide larger uncertainty, but more accurate results, so we look forward to working through those calculations.