MainPage:Nuclear:DVCS-3

From cua_phy
Revision as of 10:22, 30 June 2017 by Ali (talk | contribs)
Jump to navigation Jump to search
⇐ Back to the Main_Page

DVCS-3 Updates

  • Deadtime analysis in progress: main goals include
  • Determine the livetime/deadtime correction factor (LTCF)
  • Take a trigger rate/live rate and normalize using the current, adjust to the prescale, and then apply the LTCF.
  • To make sure the deadtime is correctly computed, the deadtime, current and prescale factors should be in agreement more than 1%, especially for the range of rates in which the deadtime is linear.
  • Currently analyzing run taken in April 2016, 13418 which was a dedicated run for the deadtime analysis, at three different currents (10, 15, 20 uA) using a liquid hydrogen target.
  • There are other dedicated deadtime runs taken in February 2016 with a carbon target, 12471 to 12476 at a current of ~5 uA with different prescale factors ( ).

Deadtime Analysis

Brief Overview

DVCS-3 was an experiment that ran from 2015-2016 in Hall A (E12-06-114) is one of the first experiments of the 12 GeV era. The method of DVCS is the cleanest way to access Generalized Parton Distributions (GPDs). The deadtime is defined as the ratio of the number of "live" events going into the electronics or computers to the total number of events. The deadtime calculations are crucial for the calibration process after the experiment. The electronic and computer deadtime need to be quantified to eventually extract precision measurements of the cross section, and thus obtain the neutral pion form factor.

Detectors in the HRS

There are three detectors that work within the HRS (High Resolution Spectrometer): the S0, S2, and the Cherenkov Detector.

Definitions

  • Scalars - each detector has two types of scalars, internal and external.
    • External Scalars (borrowed from here)
    1. 512ns clock from DVCS trigger crate (1)
    2. DVCS cosmic trigger
    3. s0
    4. s2
    5. CER
    6. EDTM
    7. DVCS external clock or LED trigger
    8. ARS_stop
    9. ARS_valid
    10. DVCS calorimeter ADC_gate
    11. inverted S0
    12. inverted S2
    13. inverted CER
    14. L1A
    15. CaloBlock001
    16. External S2M_CER
    17. 64ns clock from DVCS trigger crate
    18. 512ns clock from DVCS trigger crate (2)
    19. Master_OR
    20. Master_OR_Live
    21. HRS_Single
    22. S2M_CER
    23. S2M_CER_Scaled
    24. 103kHz clock from spectrometer
    25. BCM signal

Beam Current Monitor (BCM) - Beam Position Monitor (BPM) -

Plots from run 13418: dedicated deadtime analysis run

xx
xx
Histogram displaying S0, S2 and the Cherenkov Detector's livetime. We can see that since the Cerenkov detector has the shortest livetime, its deadtime dominates compared to the other detectors.
xx
xx
xx
xx
xx

Important ELog Updates