General Meeting Summary 10/18/17

From cua_phy
Jump to navigation Jump to search

DETECTORS AT JLAB

SHMS AEROGEL CHERENKOV

  • Discussion about recent cosmic run results and PMT response
  • Noise in raw time spectra - possibly due to noise that was not visible during KPP because of smaller time window (160 ns vs 400 ns) and cosmic vs. real data taking differences (e.g. tracking requirements)
  • One PMT (channel #6 negative - see slides) needs to be replaced. Use one of the XP4572 from detector that was at CERN (List of these PMTs).

NEUTRAL PARTICLE SPECTROMETER

  • Purchase order for dimension measurement instrument submitted
  • Discussion that need to measure dimensions of both, crystals and PMTs (requirement on PMTs is 19.2mm diameter)
  • Work on database to store individual crystal information ongoing
  • Discussion of crystal characterization results from about 20% of the crystals

DIRC

  • Making progress - in process of preparing bars for transportation


CERN DETECTORS

  • Discussion about ongoing Fermilab based statistics course and grant writing activities
  • Discussion about instrumentation for CUA clean room


DATA ANALYSIS

  • Preparing for APS DNP meeting