Difference between revisions of "MainPage:Nuclear:Summer2013:RadiationEffectsPlants"

From cua_phy
Jump to navigation Jump to search
Line 28: Line 28:
  
 
[[File:TestRunes.png|thumb|border|left|middle|upright=3|||''Fig. 1'': Chart of all test runs with the machine.]]
 
[[File:TestRunes.png|thumb|border|left|middle|upright=3|||''Fig. 1'': Chart of all test runs with the machine.]]
 +
 +
<br />
 +
<br />
 +
<br />
 +
<br />
 +
<br />
 +
<br />
 +
<br />
 +
<br />
 +
  
 
=== Random Coincidences ===
 
=== Random Coincidences ===
  
 
Sometimes, electrons pass through the two scintillators of the detector and are incorrectly counted as muons, resulting in random coincidences. In order to decrease the amount of random coincides, we will test the cosmic ray detector with 3 and even 4 panels and compare the change in count and analyze each individual coincidence (i.e. when there is a coincidence between panels 1 and 2, 2 and 3, etc.). In order to test with more than 3 detectors, we have begun construction of a third scintillator paddle. We are making it the same size as the current detectors in order to make the calculations for trigger efficiency easier. Currently we are in the sanding stage of the scintillator.
 
Sometimes, electrons pass through the two scintillators of the detector and are incorrectly counted as muons, resulting in random coincidences. In order to decrease the amount of random coincides, we will test the cosmic ray detector with 3 and even 4 panels and compare the change in count and analyze each individual coincidence (i.e. when there is a coincidence between panels 1 and 2, 2 and 3, etc.). In order to test with more than 3 detectors, we have begun construction of a third scintillator paddle. We are making it the same size as the current detectors in order to make the calculations for trigger efficiency easier. Currently we are in the sanding stage of the scintillator.
 +
 
=== PMT Testing ===  
 
=== PMT Testing ===  
  

Revision as of 16:04, 23 July 2013

⇐ Back to Summer 2013
⇐ Back to the Main_Page

Brief Description of Goals

General

This experiment will test the effect of different levels and types of radioactivity in radioisotopes on bean plants' growth and development. Additionally, after the form and dosage level that has the greatest impact on the plants is determined, it will be applied to the plant at different stages of development (i.e. germination, 1 week after germination, 2 weeks after germination, etc). This research is significant because these radioisotopes are utilized in everyday life including the use of Am-241 in smoke detectors and medical diagnostics; Cs-137 in cancer treatment; and Sr-90 in bone cancer treatment and eye treatment.

Cosmic Ray Detector

The purpose of this detector is to establish the best scintillator size and number to determine an uncertainty of the fluctuation of cosmic radiation which contributes to the uncertainty of the overall radiation effecting the plants being tested. It also provides a method to check the dosage of the varying types of radiation from the following radioisotopes.

This website provides in-depth directions on how to construct a cosmic ray detector, and it's instructions provide us with a backbone from which we can design our own detector [1]

We still need to redo the flux calculations based on the method that Nathaniel used.

Preliminary Test Results

Running the muon counter for a cycle of 24 hours (1440 minutes) a total of 1948 counts were recorded. At different times during Wednesday, July 7th, the count number was recorded in order to monitor for any jumps in the data. Fig. 1, Fig. 2, and Fig. 3 are graphs depicting the data collection.

A second test was run with the computer counting coincidences in addition to the counting module. After 24 hours the two counters were the same, however after the weekend, the counters were off by a factor of about 2,500 counts. The computer was the lower of the counts. After 94 hours, the percent difference of the computer to the count per minute of Nathaniel's test from last semester is 16%. The recent test had 1.26 count per minute on the computer compared to 1.5 count per minute of Nathaniel's test. The module had 1.66 counts per minute and a 11% deviation from Nathaniel's tests.

At 1:40, on July 16th, a new count began in setting A to compare the count on the computer and counter in the different settings.

Error creating thumbnail: Unable to save thumbnail to destination
Fig. 1: Chart of all test runs with the machine.










Random Coincidences

Sometimes, electrons pass through the two scintillators of the detector and are incorrectly counted as muons, resulting in random coincidences. In order to decrease the amount of random coincides, we will test the cosmic ray detector with 3 and even 4 panels and compare the change in count and analyze each individual coincidence (i.e. when there is a coincidence between panels 1 and 2, 2 and 3, etc.). In order to test with more than 3 detectors, we have begun construction of a third scintillator paddle. We are making it the same size as the current detectors in order to make the calculations for trigger efficiency easier. Currently we are in the sanding stage of the scintillator.

PMT Testing

Error creating thumbnail: Unable to save thumbnail to destination
Fig. 2
Error creating thumbnail: Unable to save thumbnail to destination
Fig. 3

To construct a third paddle for the trigger efficiency test, a 2 inch PMT had to be tested to ensure that it works. To do this, we used the LED test using the dark box in the lab. We used a voltage of -1490 volts, a pulse period of 10 μs, a pulse duration of 5 μs, an intensity of 10 (no units), an amplitude of ±5.0 V, a pulse width of 100 ms, and a pulse delay of 100 ms. With this test, we collected data seen in Fig. 2 and Fig. 3










Sources Available

Radioactive Isotopes
Source Initial Activity Input Date Current Activity Radioactive Particle Distribution
Bi-210 12 μCi 11/3/1972 0 μCi β- and a little alpha
Cs-137 2.3 μCi 7/1/1988 1.3 μCi Gamma and Beta
Cs-137 17.8 μCi 10/15/1965 5.92 μCi Gamma and Beta
Cs-137 3.86 μCi 10/15/1965 1.28 μCi Gamma and Beta
UO2 - Ore (1.90 g) Alpha
Am-241 0.1 μCi 10/1965 0.09 μCi Primarily emits alpha, but also gamma
Co-60 unknown Gamma and Beta
Ru-106 5.5 μCi 2/2/1977 1.05E-10 μCi Beta
Sr-90 0.1 μCi 6/2003 0.1 μCi Beta and infrequently gamma
Sr-90 0.1 μCi 6/2003 0.1 μCi Beta and infrequently gamma

Experimental Setup

To begin our experiments, we will test the effect of different low dosages and types of radiation (beta and gamma) on bean plants. After completing this portion of the experiment, we will select the dose that stimulated plant growth the most, and use it to test the effect of radiation on plants at different stages of development. To ensure that the plants germinate naturally, and without any radiation, we will germinate them in moist paper towels placed in plastic bags. This should reduce any unexpected deaths prior to germination and quicken the germination process. The seeds that germinate will be transferred to the soil in one of five cardboard boxes (33 by 33 cm). There will be two levels of independent variable in each box, and four repeated trials (two boxes per form of radiation). Therefor, for each type of radiation, there will be four levels of independent variables (total dose). To calculate the total dose, we are utilizing an online calculator, which calculates the expected dose and then we subtracted the attenuation of the soil from that number. Our dose levels (as displayed below) are relatively low, so it is not certain that they will have major or even any effect on the plants at all.

Dosages of Sources
Distance from Source (cm) Cesium-137 (mrem/hr) Cesium-137 through the soil (mrem/hr) Total Gamma Dose (mrem) Strontium-90 (mrem/hr) Total Beta Dose (mrem)
5.00 0.670 0.187 2.01 2.18 13.0
5.59 0.536 0.130 1.60 1.78 5.34
8.00 0.262 0.023 0.861 0.802 2.41
8.94 0.210 0.016 0.678 0.634 1.90


After this experiment, we will test the dosage with the most drastic results bean plants at different stages of development. The following stages will be tested: the seeds before they are placed in paper towels, germination, sapling (one week), and nearing adult (two to three weeks), and adult (over 3 weeks). We will expose the different plants for one week and compare them to a control with no radiation exposure. However, if dosages in the previous experiment have no effect on the plant growth, the layout of the next experiment will be modified.

On Tuesday, July 9th, 120 bean seeds were wrapped in wet paper towels, placed in two plastic bags, and tapped to a window. This method, instead on placing the seeds in soil, causes them to germinate quicker: these beans seeds were supposed to germinate in six to eight day, yet most of the seeds germinated by today (two days). The 105 Stringless Blue Lake bean plants will be used to test the different forms and dosages of radiation, while the 80 Top Notch Golden Wax Bush seeds will be used to test radiation's effect at different stages of development.

On Monday, July 15th, the seeds were transplanted into soil filled pots and placed by the window. The larger pots receive 500 mL of water each day, while the smaller pots receive 50 mL of water each day. The larger pots are to test the dosages displayed in the table above, while much larger dosages will be tested with the smaller pots. All of the plants will be left without radiation for several days in order to ensure that none were injured during the transplant.

On Tuesday, July 16th, the 20 Top Notch Golden Wax Bush seeds were transplanted and 10 more seeds were placed in the wet paper towels to germinate.

On Thursday, July 18th we began exposing the plants to radiation. The larger pots were exposed for three hours daily, while the smaller pots were exposed for seventeen hours.

Radioactive Isotopes
Source Current Activity Radioactive Particle Distribution Radiation 1 cm from source (mrem/hr) Radiation Through the Soil(mrem/hr) Total Radiation(mrem/hr)
Cs-137 1.3 μCi Gamma and Beta 3.679 2.865 19.632
Cs-137 5.92 μCi Gamma and Beta 16.753 13.047 89.400
Cs-137 1.28 μCi Gamma and Beta 3.622 2.821 16.508
Am-241 0.09 μCi Alpha and Gamma 0.013 0.010 0.069
Sr-90 0.1 μCi Beta 63.575 0 190.725
Sr-90 0.1 μCi Beta 63.575 0 190.725


Fig. 5: Shielding for the boxes of plants undergoing radioactive treatment. On the left is the box subjected to beta radiation and on the right is the box subjected to gamma radiation.






























Radiation and Aerogel

As a result of exposure to radiation, signs of yellowing have been found in aerogel tiles. Therefore, we will also explore the effect of beta and alpha radiation on aerogel.

Error creating thumbnail: Unable to save thumbnail to destination
Fig 2: Top view of broken aerogel tile before exposure to Sr-90.
Error creating thumbnail: Unable to save thumbnail to destination
Fig 3: Data recorded from first transmission test run on 7/19/2013
Error creating thumbnail: Unable to save thumbnail to destination
Fig 4: Side view of broken aerogel tile before exposure to Sr-90.


After being exposed to Strontium-90 for approximately twenty four hours, the aerogel's color did not change. At 90 hours, there is still no discernible discoloration.

Another aerogel tile was exposed to Cesium-137 at 1:45 on July 16th, in order to compare the effect of gamma and beta radiation on the tiles.

There are still no signs of any color change, but on the 19th, a transmittance test will take place. The tiles may also just need more time to experience any sort of color change.

A transmission test was run on 7/19/2013 at approximately 11:30 am. Although this data suggests that the tiles exposed to radiation for longer have less transmission at higher wavelengths, this can most likely be explained by the fact that those tiles accumulated dust while in their lead shielding, causing their transmittance to go down.



















Phillips Scientific Model 417 NIM Pocket Pulsar Test

Error creating thumbnail: Unable to save thumbnail to destination
Fig 5: Screenshot of oscilloscope with signal from pocket pulsar .

We tested the newly acquired pocket pulsar in order to ensure that we were getting a signal. The signal emmited from the pulsar is approximately -1 V and has a duration of approximately 12 ns.