Difference between revisions of "MainPage:Nuclear:NPScalorimeter"
Jump to navigation
Jump to search
Line 8: | Line 8: | ||
== Latest news == | == Latest news == | ||
− | * NPS meeting 10 December at 9:00 AM (EST) | + | * NPS meeting 10 December at 9:00 AM (EST) [https://wiki.jlab.org/cuawiki/index.php/Meetings Link to Meeting Agenda and Summaries] |
* NPS crystal testing facilities: CUA/CU (US), IPN-Orsay/Giessen (EU) | * NPS crystal testing facilities: CUA/CU (US), IPN-Orsay/Giessen (EU) |
Revision as of 13:31, 22 November 2015
⇐ Back to the Main_Page |
The Neutral Particle Spectrometer
Latest news
- NPS meeting 10 December at 9:00 AM (EST) Link to Meeting Agenda and Summaries
- NPS crystal testing facilities: CUA/CU (US), IPN-Orsay/Giessen (EU)
- Two presentations related to NPS at the DNP2015 (ERK in PH0006, TH in NH0004)
- NPS is mentioned in the DOE NSAC 2015 Long Range Plan - Reaching for the Horizon (p.16 (24))
- 30 PbWO4 crystals from SICCAS arrived - testing to start soon
- CUA and IPN-Orsay receive award from EIC detector R&D for crystal procurement and crystal quality tests
- Congratulations to the NPS collaboration! We were awarded with the NSF MRI (PHY-1530874), so now we can start building the Neutral Particle Spectrometer!
- Received 4+4 BTCP crystals and 1 CRYTUR crystal for testing
Components characterization and detector construction
Detector Construction |
⇒ | x150px Pictures |
![]() Detector design |
![]() Reference Material | |
| |||||
PWO crystals characterization |
⇒ | ![]() Light transmittance |
![]() Radiation hardness |
x150px Light yield |
|
| |||||
Other components | ⇒ | x150px Photomultipliers and photodiodes |
x150px Temperature stabilizer frame |
x150px Digitizing electronics |
|
| |||||
Simulations | ⇒ | x150px Detector resolution |
NPS Crystal Test Planning
Summary from 10/27/2015 meeting
Participants: MAPC, SA, TH, MB, ILP
Measurement of Transmittance using Spectrometer Lambda 750
Transverse Transmittance (stepper motor)
- Testing Subset of Crystals
- Micro-switch to be bypassed for operation with opened door?
- Can anything be damaged if someone opens the machine while operating it?
- Would any accidental light leak be detrimental to the experiment?
- See Perkin-Elmer L750 manual
- Contact company to find out more info (MAPC, Marek)
- Conceptual Test for the stepper motor inside the spectrometer
- Next week: (11/2 – 11/6) - Test with a black cloth.
Longitudinal Transmittance
- Testing Subset of Crystals
- What is the purpose of the windows? Should we remove them?
X-ray Irradiation
- Check with CUA radiation safety before testing machine. (TH, Miguel P., ILP)
- Can we move instrument downstairs?
- Clean room in which instrument is located
- Consult CP160 manual (Miguel P., NP group)
- Check radiation requirements
- Think about measurement of accumulated dose. Is there something in the instrument?
- Search for options of dosimeters (CUA/JLab/internet).
- Check out instrument
- Calibration scheduling (TH, ILP, Miguel P.).
Additional Points
- Talk with Miguel to inform him of everyone that is working with the spectrometer.
- Build a dark box as a more permanent solution for crystal measurements. (2016, when we have more crystals, NPS group)
To Be Discussed
- NPS frame construction startup (once design drawings ready, est. early 2016)
- NPS magnet construction startup (once design drawings ready, est. early 2016)
The NPS Collaboration at Jefferson Laboratory
- Institution1
- Name 1
- Name 2
- Institution2
- Name 1
- Name 2