Difference between revisions of "MainPage:Nuclear:NPScalorimeter"
Jump to navigation
Jump to search
Line 8: | Line 8: | ||
== Latest news == | == Latest news == | ||
− | <font color="red"><b>Congratulations to the NPS collaboration!</b></font> We were awarded with the NSF MRI, so now we can start building the Neutral Particle Spectrometer! | + | * 30 PbWO4 crystals from SICCAS arrived - testing to start soon |
+ | |||
+ | * CUA and IPN-Orsay receive award from EIC detector R&D for crystal procurement and crystal quality tests | ||
+ | |||
+ | * <font color="red"><b>Congratulations to the NPS collaboration!</b></font> We were awarded with the NSF MRI, so now we can start building the Neutral Particle Spectrometer! | ||
== Components characterization and detector construction == | == Components characterization and detector construction == |
Revision as of 19:05, 1 November 2015
⇐ Back to the Main_Page |
The Neutral Particle Spectrometer
Latest news
- 30 PbWO4 crystals from SICCAS arrived - testing to start soon
- CUA and IPN-Orsay receive award from EIC detector R&D for crystal procurement and crystal quality tests
- Congratulations to the NPS collaboration! We were awarded with the NSF MRI, so now we can start building the Neutral Particle Spectrometer!
Components characterization and detector construction
Detector Construction |
⇒ | x150px Pictures |
![]() Detector design |
![]() Reference Material | |
| |||||
PWO crystals characterization |
⇒ | ![]() Light transmittance |
x150px Radiation hardness |
x150px Light yield |
|
| |||||
Other components | ⇒ | x150px Photomultipliers and photodiodes |
x150px Temperature stabilizer frame |
x150px Digitizing electronics |
|
| |||||
Simulations | ⇒ | x150px Detector resolution |
NPS Crystal Test Planning
Summary from 10/27/2015 meeting
Participants: MAPC, SA, TH, MB, ILP
Measurement of Transmittance using Spectrometer Lambda 750
Transverse Transmittance (stepper motor)
- Testing Subset of Crystals
- Micro-switch to be bypassed for operation with opened door?
- Can anything be damaged if someone opens the machine while operating it?
- Would any accidental light leak be detrimental to the experiment?
- See manual
- Contact company to find out more info (MAPC, Marek)
- Conceptual Test for the stepper motor inside the spectrometer
- Next week: (11/2 – 11/6) - Test with a black cloth.
Longitudinal Transmittance
- Testing Subset of Crystals
- What is the purpose of the windows? Should we remove them?
X-ray Irradiation
- Check with CUA radiation safety before testing machine. (TH, MAPC, ILP)
- Can we move instrument downstairs?
- Clean room in which instrument is located
- Consult manual (MAPC, NP group)
- Check radiation requirements
- Think about measurement of accumulated dose. Is there something in the instrument?
- Search for options of dosimeters (CUA/JLab/internet).
- Check out instrument
- Calibration scheduling (TH, ILP, MAPC).
Additional Points
- Talk with Miguel to inform him of everyone that is working with the spectrometer.
- Build a dark box as a more permanent solution for crystal measurements. (2016, when we have more crystals, NPS group)
To Be Discussed
- NPS frame construction startup (once design drawings ready, est. early 2016)
- NPS magnet construction startup (once design drawings ready, est. early 2016)
The NPS Collaboration at Jefferson Laboratory
- Institution1
- Name 1
- Name 2
- Institution2
- Name 1
- Name 2