LogBook on the CODA data acquisition, at CUA

Page 4, [3], [2], [1].

LogBook - Page 04
Run Number Date User PMT High Voltage Experiment Description and observations Image
1095 12/05/2012 Marco (Hamamatsu) -1.80 (Camac) Gain Using plastic dark box, with LED pulse with 7 (on 5V) at 3.5 (on 15ns) with ~1kHz. It is important to note that the PMT pulse has ~30ns and the integration window has 60ns (the maximum from the coincidence module). If the pulse arrives too delayed (~+20ns), part of it may be outside the the integration window. File:1095.png
1096 12/05/2012 Marco (Hamamatsu) -1.80 (Camac) Gain Repeating run #1095 with the minimum light that still give some pulses once in a while.